ANSI porcelain post insulator for substations specifications:

ANSI Class
208
227
-
Basic Impulse Insulation Level (KV)
150
150
150
Usual Line Voltage (KV)
23
23
23
Leakage distance/in (mm)
24(610)
24(610)
24(610)
Cantilever Strength/Ib (KN)
2000(8.9)
4000(17.8)
8000(35.6)
Tensile Strength/Ib (KN)
10000(44.5)
20000(89)
28000(124.5)
Torsional Strength/in-Ib (N.m)
8000 (35.6)
16000(71.1)
40000(177.9)
Compression Strength /Ib (KN)
10000(44.5)
20000(89)
40000(177.9)
Critical Impulse Flashover Voltage, Positive (KV)
170
170
170
 
Withstand Voltage
Low Frequency, Wet/KV
60
60
60
Impulse/KV
150
150
150
Radio-Influence Voltage Data
Test Voltage to ground/kV
15
15
15
Maximum RIV at 1000 KHZ/µV
100
100
100
Height-“H”/in (mm)
14(356)
15(381)
15(381)
Shed diameter/in (mm)
6-1/2(165)
9(229)
8-1/4(216)
Bolt circle diameter/in (mm)
3(76)
5(127)
5(127)
(4)Tapped holes, size/in
1/2-13
5/8-11
5/8-11
Cap diameter-“C”/in (mm)
4-1/4(108)
6-1/4(159)
6-1/4(159)
Net Weight/Ib (kg)
26(11.6)
58(25.8)
54(24.0)

 

ANSI Class
210
231
-
Basic Impulse Insulation Level(KV)
200
200
200
Usual Line Voltage(KV)
34.5
34.5
34.5
Leakage distance/in(mm)
37(940)
37(940)
37(940)
Cantilever Strength/Ib (KN)
2000(8.9)
4000(17.8)
8000(35.6)
Tensile Strength/Ib (KN)
12000(53.4)
25000(111.2)
28000(124.5)
Torsional Strength/in-Ib (N.m)
10000 (44.5)
20000(89)
40000(177.9)
Compression Strength /Ib (KN)
15000(66.7)
30000(133.4)
60000(266.9)
Critical Impulse Flashover Voltage, Positive (KV)
225
225
225
 
Withstand Voltage
Low Frequency, Wet/KV
80
80
80
Impulse/KV
200
200
200
Radio-Influence Voltage Data
Test Voltage to ground/kV
22
22
22
Maximum RIV at 1000 KHZ/µV
100
100
100
Height-“H”/in (mm)
18(457)
20(508)
20(508)
Shed diameter/in (mm)
6-7/16(164)
9(229)
8-7/8(225)
Bolt circle diameter/in (mm)
3(76)
5(127)
5(127)
(4)Tapped holes, size/in
1/2-13
5/8-11
5/8-11
Cap diameter-“C”/in (mm)
4-1/4(108)
6-1/4(159)
6-1/4(159)
Net Weight/Ib (kg)
32(14.2)
75(33.4)
80(35.6)

 

ANSI Class
214
267
-
Basic Impulse Insulation Level (KV)
250
250
250
Usual Line Voltage (KV)
46
46
46
Leakage distance/in (mm)
43(1092)
43(1092)
43(1092)
Cantilever Strength/Ib (KN)
2000(8.9)
4000(17.8)
7000(31.1)
Tensile Strength/Ib (KN)
14000(62.3)
25000(111.2)
28000(124.5)
Torsional Strength/in-Ib (N.m)
12000 (53.4)
20000(89)
40000(177.9)
Compression Strength /Ib (KN)
15000(66.7)
60000(266.9)
60000(266.9)
Critical Impulse Flashover Voltage, Positive (KV)
280
280
280
 
Withstand Voltage
Low Frequency, Wet/KV
100
100
100
Impulse/KV
250
250
250
Radio-Influence Voltage Data
Test Voltage to ground/kV
30
30
30
Maximum RIV at 1000 KHZ/µV
200
200
200
Height-“H”/in (mm)
22(559)
24(610)
24(610)
Shed diameter/in (mm)
7-1/4(184)
9(229)
8-7/8(225)
Bolt circle diameter/in (mm)
3(76)
5(127)
5(127)
(4)Tapped holes, size/in
1/2-13
5/8-11
5/8-11
Cap diameter-“C”/in (mm)
4-1/4(108)
6-1/4(159)
6-1/4(159)
Net Weight/Ib (kg)
41(18.2)
85(37.8)
87(38.7)

 

ANSI Class
216
278
-
Basic Impulse Insulation Level (KV)
350
350
350
Usual Line Voltage (KV)
69
69
69
Leakage distance/in (mm)
72(1829)
72(1829)
72(1829)
Cantilever Strength/Ib (KN)
1500(6.7)
3000(13.3)
5000(22.2)
Tensile Strength/Ib (KN)
16000(71.2)
25000(111.2)
28000(124.5)
Torsional Strength/in-Ib (N.m)
15000 (66.7)
40000(177.9)
40000(177.9)
Compression Strength /Ib (KN)
25000(111.2)
60000(266.9)
60000(266.9)
Critical Impulse Flashover Voltage, Positive (KV)
390
390
390
 
Withstand Voltage
Low Frequency, Wet/KV
145
145
145
Impulse/KV
350
350
350
Radio-Influence Voltage Data
Test Voltage to ground/kV
44
44
44
Maximum RIV at 1000 KHZ/µV
200
200
200
Height-“H”/in (mm)
30(762)
30(762)
32(813)
Shed diameter/in (mm)
7-3/4(197)
9-3/4(248)
12-7/8(327)
Bolt circle diameter/in (mm)
3(76)
5(127)
5(127)
(4)Tapped holes, size/in
1/2-13
5/8-11
5/8-11
Cap diameter-“C”/in (mm)
4-1/4(108)
6-1/4(159)
6-1/4(159)
Net Weight/Ib (kg)
74(32.9)
110(48.9)
204(92.6)

These units are not furnished with mounting bolts. State size at the time of inquiry if mounting bolts are required.
Light gray, chocolate brown or semi-conducting glaze is available
 


Relative Articles:
Baroda bushing & insulators
Oil or SF6 transformer dry type termination
BS pin type insulators
BS type Shackle insulator drawings and specifications
Bracket

Orient is an international line post insulator manufacturer and supplier of high quality porcelain line post insulators and porcelain pin post insulator.
Copyright ©Zhengzhou Orient Power Co., Ltd. All Rights Reserved.     sales@orientinsulators.com     Tel: +86 13673997131