PDF
Prefabricated branch cable class

Prefabricated branch cable class is introduced in this article through prefabricated branch cable trunk cable and feeder cable specifications, cable structure, etc.

Prefabricated branch cable trunk cable and feeder cable specifications:

Trunk cable section (mm2)
Feeder cable section (mm2)
10
6
10
 
 
 
 
 
 
 
 
 
 
 
 
16
6
10
16
 
 
 
 
 
 
 
 
 
 
 
25
6
10
16
25
 
 
 
 
 
 
 
 
 
 
35
6
10
16
25
35
 
 
 
 
 
 
 
 
 
50
6
10
16
25
35
50
 
 
 
 
 
 
 
 
70
6
10
16
25
35
50
70
 
 
 
 
 
 
 
95
6
10
16
25
35
50
70
95
 
 
 
 
 
 
120
6
10
16
25
35
50
70
95
120
 
 
 
 
 
150
6
10
16
25
35
50
70
95
120
150
 
 
 
 
185
6
10
16
25
35
50
70
95
120
150
185
 
 
 
240
6
10
16
25
35
50
70
95
120
150
185
240
 
 
300
6
10
16
25
35
50
70
95
120
150
185
240
300
 
400
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
6
10
16
25
35
50
70
95
120
150
185
240
300
400
630
6
10
16
25
35
50
70
95
120
150
185
240
300
400

Prefabricated branch cable structure:

Trunk cable mm2
Extension Cables mm2
Reference dimensionmm
Schematic tap
d1
d2
L
10
~10
54
35
95
16
~16
25
~25
35
~35
50
~50
57
38
95
70
~70
 
 
 
 
95
~95
120
~120
78
52
145
150
~150
185
~185
240
~240
96
70
160
300
~300
400
~400
500
~400
106
80
170
630
~400

Standard trunk cables and extension cables are based on models with the corresponding insulation and sheath materials, with reference to IEC, GB, JIS and other standards made of low-voltage power cable. General Cable is a single trunk or multi-core twisted (two core five-core cable), Extension cable with single core cables. The structural characteristics are as follows:
Non-fire resistant cable structure: Single-core cable and Four core twisted cable
Fire-resistant cable structure: Single-core cable and Five core twisted cable

The structure of the branch connector: Prefabricated branch cable connection part of the body using special PVC or synthetic materials, such as cable connections shown on the right branch of the body.

Main technical performance prefabricated branch cable:

No.
Project
Performance requirements
1
Insulation
AC 3.5 kV/5min
2
Insulation resistance
≥200MΩ
3
Branch joint resistance ratio
Branch joint resistance ratio kj≤1.2
4
Short circuit test
After a short circuit ratio of rate of change of DC resistance Yj≤0.2
5
Thermal cycling test
Determination of the value of 25 cycles:≤75℃
 
 
No. 26-125 cycles measured values         , the temperature rise of less than 25 cycles measured value +8 ℃
6
Flame Retardant
Ignition off within 15 seconds
7
Enhance the fitting
Tensile pull
24h, 2 times the weight does not place the
Insulation voltage
3.5kV/5min
Insulation resistance
≥200MQ
8
Molded plastic
Room temperature
Tensile pull
≥10MPa
Elongation
≥120%
Heating
Tensile pull
Before heating 85%
Elongation
Before heating 80%
Oil
Tensile pull
Before heating 85%
Elongation
Before heating 860%
Cold-resistant
Test is not broken
 
Heat distortion
Thickness reduction rate of less than 50%
 


Relative Articles:
Advantages and applications of Composite Cross Arm Tower
Cable
The Power Substations development history
Install dimension of termination
Straight line type strain clamp

Orient is an international line post insulator manufacturer and supplier of high quality porcelain line post insulators and porcelain pin post insulator.
Copyright ©Zhengzhou Orient Power Co., Ltd. All Rights Reserved.     sales@orientinsulators.com     Tel: +86 13673997131