XLPE Insulated electrical cable for rated voltage 3.6/6kV ~26/35kV is a kind of power cable, which consists of conductor, screen, insulation, binder and over sheath. The type of cable is as following chart.
XLPE Insulated electrical cable for rated voltage 3.6/6kV ~26/35kV picture / structural drawing:
Single core XLPE insulation power cable for rated voltage from 3.6/6kV to 26/35kV consists of conductor, conductor screen, insulation, insulation screen, copper tape screen, binder and over sheath.
Single core XLPE insulation steel tape armored power cable for rated voltage from3.6/6kV to 25/35kV consists of conductor, conductor screen, insulation, insulation screen, copper tape screen, binder, inner sheath, stainless steel tape armour and over sheath.
Single core XLPE insulation steel wire armored power cable for rated voltage from3.6/6kV to 25/35kV consists of conductor, conductor screen, insulation, insulation screen, copper tape screen, binder, inner sheath, steel wire armour, copper wire, and over sheath.
Three-core XLPE insulation power cable for rated voltage from 3.6/6kV to 26/35kV consists of conductor, conductor screen, insulation, insulation screen, copper tape screen, filler, binder, and over sheath.
Three-core XLPE insulation steel tape armored power cable for rated voltage from 3.6/6kV to 26/35kV consists of conductor, conductor screen, insulation, insulation screen, copper tape screen, filler, binder, inner sheath, steel tape armour, and over sheath.
Three-core XLPE insulation steel wire armored power cable for rated voltage from 3.6/6kV to 26/35kV consists of conductor, conductor screen, insulation, insulation screen, copper tape screen, filler, binder, inner sheath, steel tape armour, and over sheath.
XLPE Insulated electrical cable for rated voltage 3.6/6kV ~26/35kV type:
Type
|
Cores
|
Rated Voltage KV
|
||||||
3.6/6
|
6/6
6/10
|
8.7/10
8.7/15
|
12/30
|
18/20
18/30
|
21/35
|
26/35
|
||
Nominal cross-section mm2
|
||||||||
YJV YJLV YJY YJLY
|
1
|
25-800
|
25-800
|
25-800
|
35-800
|
50-630
|
50-630
|
50-630
|
3
|
25-630
|
25-630
|
25-630
|
35-630
|
50-630
|
50-630
|
50-400
|
|
YJV22 YJLV22 YJV23 YJLV23
|
1
|
25-800
|
25-800
|
25-800
|
35-800
|
50-630
|
50-630
|
50-630
|
3
|
25-630
|
25-630
|
25-630
|
35-630
|
50-630
|
50-630
|
50-400
|
|
YJV32 YJLV32 YJV33 YJLV33
|
1
|
25-800
|
25-800
|
25-800
|
35-800
|
50-630
|
50-630
|
50-630
|
3
|
25-630
|
25-630
|
25-630
|
35-630
|
50-630
|
50-630
|
50-400
|
XLPE Insulated electrical cable for rated voltage 3.6/6kV ~26/35kV / the armored single-core cables are used for D.C. System only. As for A.C. system, the magnetic isolation should be applied on the non-magnetical armored layer or non-magnetical materials should be used.